CHARACTERISTIC | VALUE |
---|---|
PRODUCT GROUP | (FC-) VLT® AutomationDrive FC- |
SERIES | 302 |
POWER RATING | (P30K) 30 KW / 40 HP |
PHASE | (T) Three phase |
MAINS VOLTAGE | (5) 380 - 500 VAC |
ENCLOSURE | (E20) IP20 / Chassis |
RFI FILTER | (H1) RFI Class A1/B (C1) |
BRAKE - SAFE STOP | (X) No brake chopper |
LCP | (G) Graphical Loc. Cont. Panel |
COATING PCB | (C) Coated PCB |
MAINS OPTION | (X) No Mains Option |
ADAPTATION A | (X) Standard Cable Entries |
ADAPTATION B | (X) No adaptation |
SOFTWARE RELEASE | (SXXX) Latest release std. SW. |
SOFTWARE LANGUAGE PACK | (X) Standard Language Pack |
A OPTION | (A0) PROFIBUS DP MCA 101 |
B OPTION | (BX) No B Option |
C0 OPTION MCO | (CX) No C0 option |
C1 OPTION | (X) No C1 option |
C OPTION SOFTWARE | (XX) No software option |
D OPTION | (D0) MCB-107 24V DC backup |
FRAME SIZE | B4 |
TYPECODE PART 1 | FC-302P30KT5E20H1XGC |
TYPECODE PART 2 | XXXSXXXXA0BXCXXXXD0 |
PRODUCT CATALOG | Global (Standard) |
POWER 150% (HO) [KW] | 30 |
POWER 110% (NO) [KW] | 37 |
HEIGHT [MM] | 520,0 |
WIDTH W/ NO C OPTIONS [MM] | 230,0 |
DEPTH [MM] | 242,0 |
DEPTH WITH OPTION A/B [MM] | 242,0 |
KVA | 42.3 |
POWER LOSS NO [W] | 698 |
POWER LOSS NO [W] | 698 |
POWER LOSS HO [W] | 570 |
POWER LOSS HO [W] | 570 |
CONTINUOUS CURRENT (NO) [A] | 73 |
INTERMITTENT CURRENT (NO) [A] | 80.3 |
CONTINUOUS CURRENT (NO) [A] | 65 |
INTERMITTENT CURRENT (NO) [A] | 71.5 |
CONTINUOUS CURRENT (HO) [A] | 61 |
INTERMITTENT CURRENT (HO) [A] | 91.5 |
CONTINUOUS CURRENT (HO) [A] | 52 |
INTERMITTENT CURRENT (HO) [A] | 78 |
MATERIAL GROSS WEIGHT | 23.700 |
MATERIAL NET WEIGHT | 23.400 |
VENDOR | Factory DK |