CHARACTERISTIC | VALUE |
---|---|
PRODUCT GROUP | (FC-) VLT® AutomationDrive FC- |
SERIES | 302 |
POWER RATING | (P3K0) 3.0 KW / 4.0 HP |
PHASE | (T) Three phase |
MAINS VOLTAGE | (5) 380 - 500 VAC |
ENCLOSURE | (E20) IP20 / Chassis |
RFI FILTER | (H1) RFI Class A1/B (C1) |
BRAKE - SAFE STOP | (X) No brake chopper |
LCP | (G) Graphical Loc. Cont. Panel |
COATING PCB | (X) Not coated PCB |
MAINS OPTION | (X) No Mains Option |
ADAPTATION A | (X) Standard Cable Entries |
ADAPTATION B | (X) No adaptation |
SOFTWARE RELEASE | (SXXX) Latest release std. SW. |
SOFTWARE LANGUAGE PACK | (X) Standard Language Pack |
A OPTION | (AU) PROFIBUS Converter MCA114 |
B OPTION | (BX) No B Option |
C0 OPTION MCO | (CX) No C0 option |
C1 OPTION | (X) No C1 option |
C OPTION SOFTWARE | (XX) No software option |
D OPTION | (DX) No D option |
FRAME SIZE | A2 |
TYPECODE PART 1 | FC-302P3K0T5E20H1XGX |
TYPECODE PART 2 | XXXSXXXXAUBXCXXXXDX |
PRODUCT CATALOG | Global (Standard) |
POWER 160% (HO) [KW] | 3 |
HEIGHT [MM] | 268,0 |
WIDTH W/ NO C OPTIONS [MM] | 90,0 |
DEPTH [MM] | 205,0 |
DEPTH WITH OPTION A/B [MM] | 220,0 |
KVA | 4.99 |
POWER LOSS HO [W] | 116 |
POWER LOSS HO [W] | 116 |
CONTINUOUS CURRENT (HO) [A] | 7.2 |
INTERMITTENT CURRENT (HO) [A] | 11.5 |
CONTINUOUS CURRENT (HO) [A] | 6.3 |
INTERMITTENT CURRENT (HO) [A] | 10.1 |
CALCULATED GROSS WEIGHT | 5.200 |
CALCULATED NET WEIGHT [KG] | 4.900 |
VENDOR | Factory DK |